The practical use of electrets in a public health radon remediation campaign

Denman, A.R, Groves-Kirkby, C.J, Phillips, P.S, Crockett, R.G.M, Woolridge, A and Gillmore, G (2005) 'The practical use of electrets in a public health radon remediation campaign.' Journal of Environmental Radioactivity, 84 (3). pp. 375-391. ISSN 0265-931X

Official URL: https://doi.org/10.1016/j.jenvrad.2005.04.012

Abstract

As part of a long-term assessment of domestic radon in Northamptonshire, England, a batch of 50 commercially available electrets was deployed for nearly 1000 exposures, individual exposure periods ranging from one to eight weeks. Responsivity was comparable with that of recently-calibrated Durridge RAD-7 continuously-monitoring equipment. Voltage history analysis indicated mean voltage decay during manufacturers' QA assessment of 0.059 ± 0.026 V day?1, increasing to 0.114 ± 0.073 V day?1 during storage to first use and to 0.204 ± 0.49 V day?1 during inter-deployment storage. At a representative elevated radon concentration of 500 Bq m?3, the resulting perturbation is 3% over a 7-day deployment; at the typical mean Northamptonshire level of 80 Bq m?3 it approaches 22%. Each electret can be used for up to 25 measurements, which makes the technology attractive for organisational use. It is not suited for deployment by individual householders.

Item Type: Article
Keywords: radon, electret, ageing, environment, domestic property, public health
Divisions: School of Sciences
Identification Number: https://doi.org/10.1016/j.jenvrad.2005.04.012
Date Deposited: 02 Jun 2021 21:03
Last Modified: 15 Aug 2021 09:56
URI / Page ID: https://researchspace.bathspa.ac.uk/id/eprint/14094
Request a change to this item or report an issue Request a change to this item or report an issue
Update item (repository staff only) Update item (repository staff only)